1-70 XPM card replacement procedures
NT0X91
in an RLCM
(continued)
55
56
57
58
59
60
61
62
63
64
65
297-8021-547 Standard 14.02 May 2001
List the contents of the tape in your user directory by typing
>LIST T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files.
Demount the tape drive by typing
>DEMOUNT T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
Go to step 70.
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
Access the IOC disk utility level of the MAP by typing
>DSKUT
and pressing the Enter key.
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 58.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 70.
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
Access the SLM disk utility level of the MAP by typing
>DISKUT
and pressing the Enter key.
List the SLM disk volume names by typing
>LV CM