Nortel DMS-100 Series Replacement Procedures page 100

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-68 XPM card replacement procedures
NT0X91
in an RLCM
(continued)
42
43
44
45
46
47
At the MAP display
48
49
297-8021-547 Standard 14.02 May 2001
Toggle the ON/OFF/RESET switch on the power converter faceplate,
identified in step 3, to the RESET position and hold while setting CB1, on the
FSP, to the ON position. Both the converter FAIL LED and FRAME FAIL lamp
on the FSP will go OFF, release the ON/OFF/RESET switch, go to step 44.
Press the RESET button on the power converter faceplate while setting CB1,
identified in step 3, on the FSP to the ON position. The converter FAIL LED
will go OFF, release the RESET button.
Set the power switch on the NT2X09 and NT2X06 power converters on the
RMM shelf to the ON position.
Press the RESET button on the NT2X09 power converter while setting CB5,
on the FSP to the ON position. Both the converter FAIL LED and FRAME
FAIL lamp on the FSP will go off.
Remove the wrist strap.
Determine if a Converter Fail LED is lit.
If Converter Fail LED is
lit
not lit
Post the LCM that is controlled by the alarm and control card you have just
replaced by typing
>POST LCM
site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site where the LCM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM unit with the new FSP card
Load the LCM unit by typing
>LOADPM UNIT 0 CC
and pressing the Enter key.
If
message loadfile
found in directory is not
received
load passed
Do
step 80
step 48
Do
step 50
not
step 71