Nortel DMS-100 Series Replacement Procedures page 471

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

and pressing the Enter key.
24
Go to step 29.
25
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
26
Access the disk utility level of the MAP terminal by typing
>DISKUT
and pressing the Enter key.
27
List the SLM file names into your user directory by typing
>LV CM;LF file_name
and pressing the Enter key.
where
file_name
is the name of the SLM disk volume containing the file to be loaded
28
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
29
Reload the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
30
Return the ESA processor to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
31
Send any faulty cards for repair according to local procedure.
32
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up