1-280 XPM card replacement procedures
NT2X11
in an RLCM RMM
Replacing an NT2X11 card in an RMM
At your current location
1
At the MAP display
2
3
297-8021-547 Standard 14.02 May 2001
(continued)
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the TTP level of the MAP and post the line test unit to be replaced by
typing
>MAPCI;MTC;TRKS;TTP;POST T LTU ltu_no
and pressing the Enter key.
where
ltu_no
is the number of the line test unit which is to be replaced
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
RMM 0 0
DANGER
Briefly state reasons for the warning
Enter the reasons for the warning: a warning informs the
reader of a risk of service interruption, or damage to
equipment, or both.
Busy the trunks that are associated with the card to be replaced by typing
>BSY
and pressing the Enter key.
LTU
BUSY Q
COM LANG
LTU
21
DIG
STA S R DOT TE R
LO
P_IDL

Hide quick links: