Nt2X09 In An Iopac Rmm - Nortel DMS-100 Series Replacement Procedures

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-174 XPM card replacement procedures
NT2X09
in an IOPAC RMM
At the RMM
6
7
8
9
10
At the MAP terminal
11
297-8021-547 Standard 14.02 May 2001
(continued)
DANGER
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point at the top of each equipment rack, (Bay 0, 1, 2, and 3),
while handling circuit cards. This protects the cards against
damage caused by static electricity.
Power down the unit by setting the ON/OFF switch on the power converter
faceplate to the OFF position. Both the converter FAIL LED and FRAME FAIL
lamp on the MSP will be ON.
Replace the NT2X09 card using the common replacing a card procedure in
this document. When you have completed the procedure, return here.
Power up the RMM unit as follows:
Ensure the converter (NT2X09) is inserted. Set the POWER switch to the ON
position.
Press the RESET button on the power converter while setting the circuit
breaker on the MSP to the ON position. Both the CONVERTER FAIL LED
and FRAME FAIL lamp on the MSP will be ON.
If you were directed to this procedure from the Alarm Clearing Procedures ,
return to the alarm clearing procedure that directed you here. Otherwise,
continue with step 11.
Go to the PM level and post the RMM, if not already posted, and load the
RMM by typing
>PM;POST rmm_no;LOADPM
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
If
message loadfile
found in directory is
received
load passed
load failed
Do
step12
not
step29
step32