Replacing an NT6X20 in an ILCM
At the MAP terminal
1
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
2
Access the line test position (LTP) level of the MAP terminal and post the line
associated with the card to be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site lcm lsg ckt
and pressing the Enter key.
where
site
is the name of the site where the IOPAC is located
lcm
is the number of the ILCM with the faulty card
lsg
is the number of the line subgroup with the faulty card
ckt
is the number of the circuit associated with the faulty card
Example of a MAP response:
LCC PTY RNG .....LEN........
1FR
3
Check the status of the posted line.
If the line status is
manual busy (ManB)
not ManB
4
Busy the line by typing
>BSY
and pressing the Enter key.
At the IOPAC site
5
Go to the common replacing a line card procedure in this document. When
you have completed the procedure, return to this step.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
REM1 00 0 03 03
in an IOPAC ILCM
DN
STA F S LTA TE RESULT
NODIRN IDL
Do
step 5
step 4
1-829
NT6X20
(continued)