Nortel DMS-100 Series Replacement Procedures page 610

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-578 XPM card replacement procedures
NT2X90
in an RSC-S (DS-1) Model B RMM
Replacing an NT2X90 card in RSC-S RMM
At your Current Location
1
2
At the MAP terminal
3
4
297-8021-547 Standard 14.02 May 2001
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain an NT2X90 replacement card. Ensure the replacement card has the
same product equipment code (PEC), including suffix, as the card that is to
be removed.
Set the MAP display to the TTP level and post the RMM by typing
>MAPCI;MTC;TRKS;TTP;POST P RMM
and pressing the Enter key.
Example of a MAP display:
CM
MS
IOD
Net
.
.
.
TTP
0 Quit
POST
2 Post_
TTP
6–018
3 Seize_
CKT TYPE
4
OG
RMM
5 Bsy_
6 RTS_
7 Tst_
8
9 CktInfo
10 CktLoc
11 Hold
12 Next_
13 Rls_
14 Ckt_
15 Trnslvf_
16 Stksdr_
17 Pads_
18 Level_
Busy the trunk circuit on the RMM by typing
>BSY;BSY;INB;ALL
and pressing the Enter key.
Example of a MAP display:
(continued)
PM
CCS
LNS
.
.
.
.
DELQ
PM NO.
COM LANG
STA
0
20
MLT
Trks
Ext
Appl
.
.
.
BUSYQ
DIG
S
R
DOT TE RESULT
0 IDL

Hide quick links: