Nortel DMS-100 Series Replacement Procedures page 475

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT2X70 card in an HIE shelf
At your current location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
2
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC) including suffix, as the card to be removed.
At the MAP display
3
Access the PM level of the MAP display and post the outside plant module
(OPM) associated with the faulty NT2X70 card by typing
>MAPCI;MTC;PM;POST LCM site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site, where the OPM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM module in the frame
If the NT2X70 card is in
slot 25
slot 22
4
Display the P-side links of the OPM by typing
>TRNSL P
and pressing the Enter key.
Example of a MAP display:
Link
0:
Link
1:
Link
2:
Link
3
Note: In this example both the RMM and ESA modules are provisioned.
However, should either of these modules not be provisioned in your office,
skip the steps relating to that module and continue with the rest of the
procedure.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
RMM 0
0;
Cap MS;Status:
RMM 0
1;
Cap MS;Status:
ESA 0
0
Cap M ;Status:
ESA 0
1
Cap M ;Status:
in an OPM HIE
Do
step 4
step 36
OK; MsgCond:OPN
OK; MsgCond:OPN
OK; MsgCond:OPN
OK; MsgCond:OPN
1-443
NT2X70
(continued)