Nortel DMS-100 Series Replacement Procedures page 350

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-318 XPM card replacement procedures
NT2X48
in an IOPAC RMM
Replacing an NT2X48 in an RMM
At the MAP terminal
1
2
3
4
297-8021-547 Standard 14.02 May 2001
(continued)
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the TTP level of the MAP display and post the RMM that contains the
card to be replaced by typing
>MAPCI;MTC;TRKS;TTP;POST TM RMM rmm_no ckt_no to ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
ckt_no
is the number of the trunk circuit associated with the card to be
replaced
Example of a MAP response:
POST
3
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
MF RMM 0 0
LAST CIRCUIT = 3
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
Ensure the card being pulled is the correct card and is being pulled from the
correct card slot.
>CKTLOC
and pressing the Enter key.
Busy the trunks associated with the card to be replaced by typing
BSY ALL
and pressing the Enter key.
BUSY Q
COM LANG
ESADGTR
ESADGTR
DIG
STA S R DOT TE R
0
LO
P_IDL