Nortel DMS-100 Series Replacement Procedures page 381

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the MAP terminal
4
To verify the signal distribution circuits on the removed card, type
>POST P RMM rmm_no ckt_no
and press the Enter key.
where
rmm_no
is the number of the RMM shelf, the location of the replaced card
ckt_no
is the number of the first circuit and the location of the NT2X5 card.
Example of a MAP response:
LAST CIRCUIT = 14
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
13
TTP 6–006
CKT TYPE
OG TESTEQ RMM 0 0
5
To send defective cards for repair, follow the local procedures.
6
Record information for office records, as follows:
date of card replacement
serial number of the card
details or reasons for replacement of the card
Go to step 8.
7
For additional help, contact the next level of maintenance.
8
The procedure is complete.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up