1-324 XPM card replacement procedures
NT2X48
in an OPM RMM
At the RMM shelf
4
At the MAP display
5
6
7
297-8021-547 Standard 14.02 May 2001
(continued)
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point of a frame supervisory panel (FSP) while handling
circuit cards. This protects the cards against damage caused
by static electricity.
Replace the NT2X48 card using the common replacing a card procedure in
this document. When you have completed the procedure, return to this point.
Test all of the digitone receivers on the new NT2X48 card by typing
>TST
Continue testing through all four digitone circuits on the card by typing
>NEXT
If TST
passed
failed
Repost all four ESADGTR circuits by typing
>POST P RMM rmm_no ckt_no
and pressing the Enter key.
where
ckt_no
is the number of the first and last circuits on the NT2X48 card.
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
3
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG
RMM
0 0
Do
step 8
step 11
to ckt_no
1125
BUSY Q
COM LANG
ESAGDTR 11
DIG
STA S R DOT TE R
IDL