Nortel DMS-100 Series Replacement Procedures page 711

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

9
Use the following information to determine where to proceed.
If you entered this procedure
from
alarm clearing procedures
other
At the MAP terminal
10
Test the RMM by typing
>TST
and pressing the Enter key.
If TST
passed
failed
11
Return the RMM to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
12
Send any faulty cards for repair according to local procedure.
13
Record the date the card was replaced, the serial number of the card, and the
symptoms the prompted replacement of the card. Go to step 16.
Return to the Alarm Clearing Procedures that directed you to this procedure.
14
At the point where a faulty card list was produced, identify the next faulty card
on the list and go to the appropriate card replacement procedure for that card
in this manual.
15
Obtain further assistance in replacing this card by contacting operating
company maintenance personnel.
16
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an RSC-S (PCM-30) Model A RMM
Do
step 14
step 10
Do
step 11
step 14
Do
step 12
step 15
1-679
NT4X97
(end)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents