Nortel DMS-100 Series Replacement Procedures page 967

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

10
Busy ILCM unit by typing
>BSY UNIT lcm_unit
and pressing the Enter key.
where
lcm_unit
is the ILCM unit to be busied (0 or 1)
Note: For ILCM unit 0, card is in slot 19. For ILCM unit 1, card is in slot 20.
11
Post the C-side peripheral module, previously posted in step 5, where the
PRLCM is interfaced by typing
>POST host_pm host_pm_no
and pressing the Enter key.
where
host_pm
is the name of the host PM, (PLGC, RCO2)
host_pm_no
is the number of the host PM
12
Using the information collected in step 7, busy both links associated with the
faulty card by typing
>BSY LINK link_no
and pressing the Enter key.
where
link_no
is one of two links associated with the faulty card
Note: Repeat this step for the other link associated with the faulty card.
At the PRLCM cabinet
13
Change dip switch settings on the new replacement card to match the faulty
card being removed.
14
Replace the NT6X27 card using the common replacing a card procedure in
this document. When the card has been replaced, return to this step.
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
DANGER
Calls in progress may be interrupted.
The craftsperson must wait at least 15 minutes to allow calls
in progress to be completed before removing the NT6X27
PCM-30 interface card.
in an OPM HIE
1-935
NT6X27
(continued)