Nortel DMS-100 Series Replacement Procedures page 993

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Summary of replacing an NT6X30 card in RSC-S LCME
Access PM level
of MAP display
and post PM
Switch RG
activity to the
good RG
BSY LCME units
associated with
the faulty RG
Switch OFF the
circuit breaker
for the RG
Remove and
replace faulty
card
Set DIP switch
settings
Switch ON the
circuit breaker
for the new RG
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
in an RSC-S (DS-1) Model A LCME
Return busied
PM units to
service
Switch RG
activity to the
new RG
Test PM units
for the new RG
Align RG to
preferred RG
End of
procedure
XPM card replacement procedures
This flowchart summarizes the
procedure.
Use the instructions in the
procedure that follows this
flowchart to perform the
procedure.