Nortel DMS-100 Series Replacement Procedures page 573

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

At the RMM
5
Replace the NT2X90 card using the common replacing a card procedure in
this document. When you have completed the procedure, return here.
At the MAP terminal
6
Go to the peripheral module (PM) level of the MAP terminal and post the
RMM trunk circuits by typing
>PM;POST P RMM rmm_no ckt_no to ckt_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf where the card is to be replaced
ckt_no
is the number of the trunk circuit associated with the card to be
replaced
7
At the PM level, place the first circuit on hold and test the second circuit by
typing
>HOLD
and pressing the Enter key.
and then typing
>TST
and pressing the Enter key
If TST
passed
failed
8
Return to service the tested circuit by typing
>RTS
DMS-100 Family NA100 Card Replacement Procedures Volume 4 of 7 LET0015 and up
XPM card replacement procedures
in an OPAC RMM
WARNING
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point at the top of each equipment rack, (Bay 0, 1, 2, and 3),
while handling circuit cards. This protects the cards against
damage caused by static electricity.
Do
step 8
step14
1-541
NT2X90
(continued)