Nortel DMS-100 Series Replacement Procedures page 548

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

1-516 XPM card replacement procedures
NT2X70
in an SMS
(end)
21
At the frame
22
23
24
25
26
27
28
297-8021-547 Standard 14.02 May 2001
If TST
failed
Return the inactive SMS unit to service by typing
>RTS UNIT unit_no
and pressing the Enter key.
where
unit_no
is the number of the faulty SMS unit
If RTS
passed
failed
Remove the sign from the active SMS unit.
Send any faulty cards for repair according to local procedure.
Record the following items in office records according to local policy:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 27.
Return to the maintenance procedure that directed you to this procedure. At
the point where a faulty card list was produced, identify the next faulty card
on the list and go to the appropriate card replacement procedure for that card
in this manual.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
You have successfully completed this procedure. Return to the maintenance
procedure that directed you to this card replacement procedure and continue
as directed.
For further assistance with switch of activity, contact the personnel
responsible for the next level of support.
Note: If the system recommends using the SWACT command with the
FORCE option, consult office personnel to determine if use of the FORCE
option is advisable.
Do
step 25
Do
step 22
step 26