Honda Acura NSX 1991 Service Manual page 1070

Table of Contents

Advertisement

Starting System
1.
Inspect the armature for wear or damage due to
contact with the field coil magnets.
Inspect for
d a m a g e .
2 .
A dirty or burnt commutator surface may be resur-
faced with emery cloth or a lathe within the follow-
ing
specifications.
Commutator Diameter
Standard (New): 29.9-30.0 mm (1.177-l .I81 in)
Service
Limit
: 29.0 mm (1 .I4 in)
VERNIER CALIPER
23-84
Commutator Runout
Standard (New): O-0.02 mm (O-0.0008 in)
Service
Limit
: 0.04 mm (0.0016 in)
II
3 .
If the commutator runout and diameter are within
carbon dust or brass chips between the segments.
4.
If surface is dirty, recondition it with a #500 or
sary, undercut mica with a hacksaw blade to achieve
proper depth.
Commutator Mica Depth
Standard (New): 0.5-0.8 mm (0.019-0.031 in)
Service
Limit
: 0.2 mm (0.008 in)
D I A L
INDICATOR
COMMUTATOR
COMMUTATOR
MICA
DEPTH

Hide quick links: