Chapter 5
Setting the IEDR Threshold for Internal Errors
Viewing IEDR Settings
Viewing IEDR Settings for Hunt Groups
5-46
You can set the threshold at which the switch will shutdown a port.
By default this threshold is set to 10 internal errors in a 5-second
time period. You can set the threshold to any number between 5
and 500 internal errors in a 5-second time period. This setting is
global for all ports that have been enabled for IEDR including ports
configured for Hunt groups.
To set the IEDR threshold:
1. Enter Global Configuration mode.
The CLI displays the <configure># prompt.
2. Enter the following command:
set internal-error-threshold <threshold>
To view a list of the ports that have IEDR enabled:
1. Enter Global Configuration mode.
The CLI displays the <configure># prompt.
2. Enter the following command:
show port internal-error-config
To view the global IEDR setting for hunt groups:
1. Enter Global Configuration mode.
The CLI displays the <configure># prompt.
2. Enter the following command:
show huntgroup internal-error-config
Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, Version v5.3.1