Error Messages

System Messages

Avaya P550R, P580, P880, and P882 Multiservice Switch User Guide, Version v5.3.1
* Note: If IEDR detects errors on a port in the huntgroup, it tests
each port within that hunt group. When it finds the first
bad port, it removes it from the Hunt Group and disables
the port.
The IEDR feature may display the following error messages:
The following message indicates the IEDR feature is enabled on
the specified ports
internal-error-config enabled on port <x>/
<y>
The following message indicates that internal CRC errors are
occurring:
Description: CRC err: Rx'ed 5 bad pkts
since last poll - last from port3.2
The following message indicates that IEDR shut down a port
because its rate of internal errors exceeded the threshold:
Description: Shutdown Port 3.2 due to CRC
error exceeding threshold of 10
The set port internal-error-shutdown all-ports enable
command produces system messages similar to the following:
Upon success:
Internal-error-config enabled on port 3/1
Internal-error-config enabled on port 3/2
Internal-error-config enabled on port 4/1
Internal-error-config enabled on port 4/2
Internal-error-config enabled on port 4/3
Internal-error-config enabled on port 4/4
Slot 6 has 10/100 ethernet ports that are
unsupported and will not be set.