TCS Control Valve Assembly
Replacement
CAUTION: Be careful not to damage the TCS control valve when handling the TCS control valve assembly.
1. Disconnect the vacuum tube, breather pipe, and air hose from the intake air duct.
2. Loosen the intake air duct band screws, then remove the intake air duct.
AIR HOSE
NOTE: When installing the duct,
align the marks.
3. Disconnect the TCS control valve angle sensor connector and actuator connector.
4. Remove the TCS control valve assembly and bracket.
5. Install the TCS control valve assembly in the reverse order of removal.
TCS CONTROL VALVE ANGLE
SENSOR CONNECTOR
TCS CONTROL VALVE
ACTUATOR CONNECTOR
BREATHER PIPE
6 x 1.0 mm BOLT
12 N-m (1.2 kgf-m, 9 Ibf-ft)
BRACKET
NOTE: When installing the duct,
align the cutout with the mark.
INTAKE AIR DUCT
TCS CONTROL VALVE
ASSEMBLY
8 x 1.25 mm NUT
22 N-m (2.2 kgf-m, 16 Ibf-ft)
8 x 1.25 mm BOLT
22 N-m (2.2 kgf-m, 16 Ibf-ft)
VACUUM TUBE
INTAKE AIR DUCT
BAND SCREW