Acura 3.5 RL Manual page 1211

1996 - 2004 years
Table of Contents

Advertisement

NOTE:
• Before testing, go to the Troubleshooting Guide (see page 23-244). Be sure to go through self-diagnosis function
modes 1 and 2 (see pages
• All connector views are from the wire side of female terminals unless otherwise noted.
Multiplex Control Unit (Door):
1. Remove the driver's door panel, and disconnect the 20P connector from the door unit (see page 23-245).
2. Inspect the connector and socket terminals to be sure they are all making good contact.
• If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
• If the terminals look OK, make the following input tests at the connector.
If a test indicates a problem, find and correct the cause, then recheck the system.
If all the input tests prove OK, the power window master switch must be faulty; replace it.
Reconnect the connector to the door unit.
Cavity
Wire
Test condition
Driver's door opened
5
GRN/BLU
Driver's door closed
23-248
and 23-252).
Test: Desired result
Check for voltage to ground:
There should be less than 1 V.
Check for voltage to ground:
There should be 5 V or more.
Possible cause if result is not obtained
• Faulty driver's door switch
• Poor ground (G401, G402)
• An open in the wire