Charge until EYE shows charge is OK; plus an
additional 30 minutes to assure full charge.
NOTE: If the battery charge is very low, it may
be necessary to bypass the charger's polarity
protection circuitry.
If the EYE does not show charge is OK within
3 hours, the battery is no-good; replace it.
Write down how long the battery was
charged.
• Apply 300 amp load for 15 seconds to remove surface charge.
• Allow 15 seconds recovery period.
• Apply test load (see Test Load Chart).
• Record voltage at the end of 15 seconds.
Stays above 9.6 volts; battery is OK.
80D26R-MF
BATTERY CODE
Charge on High Setting (40 amps)
Test Load Capacity (#2)
Use the test load or 1/2 the cold cranking amps (CCA) printed on the
label on the top of the battery. If neither is indicated, use the
information below:
BATTERY
CODE
80
Drops below 9.6 volts; battery is no-good.
TEST LOAD CHART
COLD CRANKING
AMPS (CCA)
550
LOAD
(amps)
270