Install the sealing bolt to the secondary driven gear
shaft, and torque it to 20 N-m (2.0 kgf-m, 14 Ibf-ft).
TRANSMISSION
HOUSING
SEALING BOLT
20 N-m (2.0 kgf-m,
14 Ibf-ft)
SECONDARY
DRIVEN GEAR
SHAFT
DOWEL PIN
6.
With the mainshaft and countershaft removed, install
the secondary driven gear shaft, and torque the trans-
mission housing.
NOTE: Install the gasket when checking starting
torque.
8 x 1.25 mm
33 N-m (3.4 kgf-m, 25 Ibf-ft)
DOWEL PIN
GASKET
TORQUE CONVERTER
HOUSING
7.
Rotate the secondary driven gear shaft in both direc-
tions to seat the bearing.
8.
Measure the starting torque of the secondary driven
gear shaft with a torque wrench.
STANDARD: 3.4 - 4.4 N-m
(35 - 45 kgf-cm, 30 - 39 Ibf-in)
NOTE:
• Measure the starting torque at normal room tem-
perature in both directions.
• Changing the shim to the next size will increase or
decrease starting torque about 0.3 - 0.4 N-m
(3-4 kgf-cm, 3 - 4 Ibf-in).
• To increase the starting torque, increase the
thickness of the shim. To decrease the starting
torque, decrease the thickness of the shim.
TORQUE WRENCH