Recirculation Control Motor - Acura 3.5 RL Manual

1996 - 2004 years
Table of Contents

Advertisement

Recirculation Control Motor

Replacement
1. Remove the glove box (see
2.
Remove the glove box back cover (see page 22-65).
3.
Disconnect the wire harness clip and the connector
from the recirculation control motor, then remove
the self-tapping screws and the recirculation control
motor.
RECIRCULATION
CONTROL MOTOR
WIRE
HARNESS
CLIP
4.
Install in the reverse order of removal. After installa-
tion, make sure the recirculation control motor runs
smoothly.
section
20).
Test
1.
Disconnect the 4P connector from the recirculation
control motor.
2.
Connect battery power to the No. 1 terminal, and
ground the No. 2 and No. 4 terminals; the recircula-
tion control motor should run smoothly.
CAUTION: Never connect the battery in the oppo-
site direction.
RECIRCULATION
CONTROL MOTOR
4P CONNECTOR
3.
Disconnect the No. 2 or No. 4 terminals from ground;
the recirculation control motor should stop at
FRESH or RECIRCULATE.
NOTE: Don't cycle the recirculation control motor
for a long time.
4.
If the recirculation control motor does not run in
step 2, remove it, then check the recirculation con-
trol linkage and doors for smooth movement. If
they move smoothly, replace the recirculation con-
trol motor.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ka9

Table of Contents