Hydraulic Flow (cont'd)
or
Position
1. 1st Gear
The flow of fluid through the torque converter circuit is the same as in
the manual valve, the modulator valve, the line pressure control valve and the throttle valve. The line pressure (1)
becomes the modulator pressure (6) at the modulator valve, and the line pressure (4) at the manual valve. The modula-
tor pressure (6) flows to the left ends of the 1-2 shift valve and the 3-4 shift valve because shift solenoid valve A is
turned OFF and B is turned ON by the PCM. The 1-2 shift valve is moved to the right side, and uncovers the port to
allow the 1st clutch pressure (10) to the 1st clutch. The 1st clutch pressure (10) is applied to the 1st clutch, consequent-
ly, the vehicle will move as the engine power is transmitted. In
applied to the 1st-hold clutch because the manual valve covers the port leading to the 1st-hold clutch.
NOTE:
• When used, "left" or "right" indicates direction on the hydraulic circuit.
• The hydraulic circuit is for '96 - '98 models. On '99 - 01 models, the 2nd accumulator is different.
position. The line pressure (1) flows through
or
position, the 1st-hold clutch pressure is not