Udp-Echo Test Configuration Example - H3C S5500-EI series Operation Manual

Hide thumbs Also See for S5500-EI series:
Table of Contents

Advertisement

Operation Manual – NQA
H3C S5500-EI Series Ethernet Switches
Extend results:
Packet lost in test: 0%
Failures due to timeout: 0
Failures due to disconnect: 0
Failures due to no connection: 0
Failures due to sequence error: 0
Failures due to internal error: 0
Failures due to other errors: 0

1.12.8 UDP-echo Test Configuration Example

I. Network requirements
Use the NQA UDP-echo function to test the round trip time between Device A and
Device B. The port number is 8000.
II. Network diagram
Figure 1-10 Network diagram for the UDP-echo test
III. Configuration procedure
1)
Configure Device B.
# Enable the NQA server and configure the listening IP address as 10.2.2.2 and port
number as 8000.
<DeviceB> system-view
[DeviceB] nqa server enable
[DeviceB] nqa server udp-echo 10.2.2.2 8000
2)
Configure Device A.
# Create a UDP-echo test group and configure related test parameters.
<DeviceA> system-view
[DeviceA] nqa entry admin test
[DeviceA-nqa-admin-test] type udp-echo
[DeviceA-nqa-admin-test-udp-echo] destination ip 10.2.2.2
[DeviceA-nqa-admin-test-udp-echo] destination port 8000
[DeviceA-nqa-admin-test-udp-echo] quit
# Enable the UDP-echo test.
[DeviceA] nqa schedule admin test start-time now lifetime forever
# Display results of one UDP-echo test.
1-31
Chapter 1 NQA Configuration