H3C S5500-EI series Operation Manual page 1525

Hide thumbs Also See for S5500-EI series:
Table of Contents

Advertisement

Operation Manual – Track
H3C S5500-EI Series Ethernet Switches
When there is a fault on the link between Switch A and Switch C, you can still
successfully ping Host B on Host A. Use the display vrrp command to view information
about VRRP group 1.
# Display detailed information about VRRP group 1 on Switch A when there is a fault on
the link between Switch A and Switch C.
[SwitchA-Vlan-interface2] display vrrp verbose
IPv4 Standby Information:
Run Method
Virtual IP Ping : Enable
Interface
VRID
Admin Status
Config Pri
Preempt Mode
Auth Type
Track Object
Virtual IP
Master IP
# Display detailed information about VRRP group 1 on Switch B when there is a fault on
the link between Switch A and Switch C.
[SwitchB-Vlan-interface2] display vrrp verbose
IPv4 Standby Information:
Run Method
Virtual IP Ping : Enable
Interface
VRID
Admin Status
Config Pri
Preempt Mode
Auth Type
Virtual IP
Virtual MAC
Master IP
The output information indicates that when there is a fault on the link between Switch A
and Switch C, the priority of Switch A decreases to 80. Switch A becomes the backup,
and Switch B becomes the master. Packets from Host A to Host B are forwarded
through Switch B.
: VIRTUAL-MAC
: Vlan-interface2
: 1
: UP
: 110
: YES
: SIMPLE TEXT
: 1
: 10.1.1.10
: 10.1.1.2
: VIRTUAL-MAC
: Vlan-interface2
: 1
: UP
: 100
: YES
: SIMPLE TEXT
: 10.1.1.10
: 0000-5e00-0101
: 10.1.1.2
1-9
Chapter 1 Track Configuration
Adver. Timer
: 5
State
: Backup
Run Pri
: 80
Delay Time
: 5
Key
: hello
Pri Reduced
: 30
Adver. Timer
: 5
State
: Master
Run Pri
: 100
Delay Time
: 5
Key
: hello

Advertisement

Table of Contents
loading

Table of Contents