Operation Manual – PoE
H3C S5500-EI Series Ethernet Switches
Caution:
If you adjust the PD disconnection detection mode when the device is running, the
connected PDs will be powered off. Therefore, be cautious to do so.

1.8 Enabling the PSE to Detect Nonstandard PDs

There are standard PDs and nonstandard PDs. Usually, the PSE can detect only
standard PDs and supply power to them. The PSE can detect nonstandard PDs and
supply power to them only after the PSE is enabled to detect nonstandard PDs.
Follow these steps to enable the PSE to detect nonstandard PDs:
Enter system view
Enable the PSE to detect
nonstandard PDs

1.9 Displaying and Maintaining PoE

Display the mapping between ID,
module, and slot of all PSEs.
Display the power state and
information of the specified PoE
interface
Display the power information of a
PoE interface(s)
Display the information of PSE
Display all information of the
configurations and applications of
the PoE configuration file
Display all information of the
configurations and applications of
the PoE configuration file applied
to the specified PoE interface
To do...
system-view
poe legacy enable
To do...
Use the command...
Use the command...
display poe device
display poe interface
[ interface-type
interface-number ]
display poe interface power
[ interface-type
interface-number ]
display poe pse
display poe-profile [ index
index | name profile-name ]
display poe-profile interface
interface-type
interface-number
1-8
Chapter 1 PoE Configuration
Remarks
Optional
Disabled by default.