H3C S5500-EI series Operation Manual page 1147

Hide thumbs Also See for S5500-EI series:
Table of Contents

Advertisement

Operation Manual – SNMP-RMON
H3C S5500-EI Series Ethernet Switches
2.2.2 Configuration Procedure
Follow these steps to configure RMON:
Enter system view
Create an event entry in
the event table
Enter Ethernet interface
view
Create an entry in the
history table
Create an entry in the
statistics table
Exit Ethernet interface
view
Create an entry in the
alarm table
Create an entry in the
private alarm table
To do...
system-view
rmon event entry-number
[ description string ] { log |
log-trap log-trapcommunity |
none | trap trap-community }
[ owner text ]
interface interface-type
interface-number
rmon history entry-number
buckets number interval
sampling-interval [ owner text ]
rmon statistics entry-number
[ owner text ]
quit
rmon alarm entry-number
alarm-variable sampling-interval
{ absolute | delta }
rising-threshold
threshold-value1 event-entry1
falling-threshold
threshold-value2 event-entry2
[ owner text ]
rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-interval { absolute |
changeratio | delta }
rising-threshold
threshold-value1 event-entry1
falling-threshold
threshold-value2 event-entry2
entrytype { forever | cycle
cycle-period } [ owner text ]
Use the command...
2-4
Chapter 2 RMON Configuration
Remarks
Optional
Optional
Optional
Optional
Optional

Advertisement

Table of Contents
loading