Operation Manual – Information Center
H3C S5500-EI Series Ethernet Switches
II. Timestamp
Timestamp records the time when system information is generated to allow users to
check and identify system events.
Note that there is a space between the timestamp and sysname (host name) fields.
III. Sysname
Sysname is the system name of the current host. You can use the sysname command
to modify the system name. (Refer to System Maintaining and Debugging for details)
Note that there is a space between the sysname and module fields.
IV. Module
The module field represents the name of the module that generates system information.
You can enter the info-center source ? command in system view to view the module
list.
Refer to
Between "module" and "level" is a "/".
V. Level (Severity)
System information can be divided into eight levels based on its severity, from 0 to 7.
Refer to
is a forward slash between the levels (severity) and digest fields.
VI. Digest
The digest field is a string of up to 32 characters, outlining the system information.
Note that there is a colon between the digest and content fields.
VII. Content
This field provides the content of the system information.

1.2 Configuring Information Center

1.2.1 Information Center Configuration Task List

Complete the following tasks to configure information center:
Table 1-3
for module name and description.
Table 1-1
for definition and description of these severity levels. Note that there
Chapter 1 Information Center Configuration
1-6