Operation Manual – SNMP-RMON
H3C S5500-EI Series Ethernet Switches
Figure 1-1 Relationship between NMS, Agent and MIB
MIB stores data using a tree structure. The node of the tree is the managed object and
can be uniquely identified by a path starting from the root node. As illustrated in the
following figure, the managed object B can be uniquely identified by a string of numbers
{1.2.1.1}. This string of numbers is the OID of the managed object B.
1
5
A
Figure 1-2 MIB tree

1.2 SNMP Configuration

As configurations for SNMPv3 differ substantially from those of SNMPv1 and SNMPv2c,
their SNMP functionalities will be introduced separately below.
Follow these steps to configure SNMPv3:
Enter system view
Enable SNMP Agent
Configure SNMP Agent
system information
1
2
1
1
2
B
6
To do...
system-view
snmp-agent
snmp-agent sys-info
{ contact sys-contact |
location sys-location |
version { all | { v1 | v2c |
v3 }* } }
2
Use the command...
1-3
Chapter 1 SNMP Configuration
Remarks
Optional
Disabled by default
You can enable SNMP
Agent through this
command or any
commands that begin with
snmp-agent.
Optional
The defaults are as
follows:
Hangzhou H3C Tech.
Co., Ltd. for contact,
Hangzhou, China for
location, and SNMP v3 for
the version.