Power Saving Led Settings; Power Saving Port Settings - D-Link xStack Reference Manual

Xstack ds-3620 series web ui reference guide layer 3 managed stackable gigabit switch
Hide thumbs Also See for xStack:
Table of Contents

Advertisement

®
xStack
DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch Web UI Reference Guide
The fields that can be configured are described below:
Parameter
Power Saving Mode
Link Detection State
Power Saving Mode
Length Detection State
Power Saving Mode
LED State
Power Saving Mode
Port State
Power Saving Mode
Hibernation State
Action
Time Range Name
Click the Apply button to accept the changes made for each individual section.
Click the Clear Time Range to remove all the entries.

Power Saving LED Settings

This window is used to add or delete the power saving schedule on the LED of all ports.
To view the following window, click Management > Power Saving > Power Saving LED Settings, as show below:
The fields that can be configured are described below:
Parameter
Action
Time Range Name
Click the Apply button to accept the changes made for each individual section.
Click the Clear Time Range to remove all the entries.

Power Saving Port Settings

This window is used to set the power saving state.
Description
Click the radio buttons to enable or disable the link detection state. When enabled, a
port which has a link down status will be turned off to save power to the Switch. This
will not affect the port's capabilities when the port status is link up.
Click the radio buttons to enable or disable length detection state. When enabled, the
Switch will automatically determine the length of the cable and adjust the power flow
accordingly.
Click the radio buttons to enable or disable LED state. When enabled, the LED's
state of ports will be turned off during the configured time range.
Click the radio buttons to enable or disable port state. When enabled, the ports will
be shut down during the configured time range.
Click the radio buttons to enable or disable hibernation state. When enabled, the
Switch will go into a low power state and be idle during the configured time range. It
will shut down all the ports, all network function (telnet, ping, etc.) will not work, and
only the console connection will work via the RS232 port. If the Switch is an endpoint
type PSE (Power Sourcing Equipment), it will not provide power to the port.
Use the drop down menu to add or delete the schedule.
Specify the name of the schedule.
Figure 4-54 Power Saving LED Settings window
Description
Use the drop down menu to add or delete the schedule.
Specify the name of the schedule.
85

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xstack dgs-3620-28sc

Table of Contents