Power Saving Settings; Power Saving Led Settings - D-Link xstack DES-3810 series Reference Manual

Layer 3 managed ethernet switch
Hide thumbs Also See for xstack DES-3810 series:
Table of Contents

Advertisement

®
xStack

Power Saving Settings

This window allows the user to implement the Switch's built-in power saving features and set the schedule to enforce
the settings.
To view this window, click Management > Power Saving > Power Saving Settings as shown below:
The fields that can be configured are described below:
Parameter
Power Saving Mode
Link Detection State
Power Saving Mode
Length Detection State
Power Saving Mode
LED State
Power Saving Mode
Port State
Power Saving Mode
Hibernation State
Action
Time Range Name
Click the Apply button to accept the changes made for each individual section.
Click the Clear Time Range button to remove all the time ranges configured.

Power Saving LED Settings

This window is used to add or delete the power saving schedule on the LED of all ports.
To view this window, click Management > Power Saving > Power Saving LED Settings as shown below:
DES-3810 Series Layer 3 Managed Ethernet Switch Web UI Reference Guide
Figure 3-49 Power Saving Settings window
Description
When the Power Saving Mode Link Detection State is enabled, a port which has a link
down status will be turned off to save power to the Switch. This will not affect the port's
capabilities when the port status is link up.
When the Power Saving Mode Length Detection State is enabled, the Switch will
automatically determine the length of the cable and adjust the power flow accordingly.
When Power Saving Mode LED State is enabled, the LED's state of ports will be turned
off during the configured time range.
When Power Saving Mode Port State is enabled, the ports will be shut down during the
configured time range.
When Power Saving Mode Hibernation State is enabled, the Switch will go into a low
power state and be idle during the configured time range. It will shut down all the ports, all
network function (telnet, ping, etc.) will not work, and only the console connection will
work via the RS232 port. If the Switch is an endpoint type PSE (Power Sourcing
Equipment), it will not provide power to the port.
Use the drop down menu to add or delete the schedule.