Sflow Counter Poller Settings - D-Link xStack Reference Manual

Xstack ds-3620 series web ui reference guide layer 3 managed stackable gigabit switch
Hide thumbs Also See for xStack:
Table of Contents

Advertisement

®
xStack
DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch Web UI Reference Guide
From Port / To Port
Analyzer Server ID
Rate
MAX Header Size
Click the Apply button to accept the changes made.
Click the Delete All button to remove all the entries listed.
Click the Edit button to re-configure the specific entry.
Click the Delete button to remove the specific entry.

sFlow Counter Poller Settings

On this page the user can configure the sFlow counter poller parameters. If the user wants to change the analyzer
server ID, he needs to delete the counter poller and create a new one.
To view this window, click Monitoring > sFlow > sFlow Counter Poller Settings as shown below:
The fields that can be configured are described below:
Parameter
Unit
From Port / To Port
Analyzer Server ID
Interval
Click the Apply button to accept the changes made.
Click the Delete All button to remove all the entries listed.
Click the Edit button to re-configure the specific entry.
Click the Delete button to remove the specific entry.
Use the drop-down menus to specify the list of ports to be configured.
The analyzer server ID specifies the ID of a server analyzer where the packet will be
forwarded.
The sampling rate for packet Rx sampling. The configured rate value multiplied by
256 is the actual rate. For example, if the rate is 20, the actual rate 5120. One packet
will be sampled from every 5120 packets. If set to 0, the sampler is disabled. If the
rate is not specified, its default value is 0.
The sampling rate for packet Tx sampling. The configured rate value multiplied by
256 is the actual rate. For example, if the rate is 20, the actual rate 5120. One packet
will be sampled from every 5120 packets. If set to 0, the sampler is disabled. If the
rate is not specified, its default value is 0.
The maximum number of leading bytes in the packet which has been sampled that
will be encapsulated and forwarded to the server. If not specified, the default value is
128.
Figure 12-25 sFlow Counter Poller Settings
Description
Select the switch unit to configure.
Use the drop-down menus to specify the list of ports to be configured.
The analyzer server ID specifies the ID of a server analyzer where the packet will be
forwarded.
The maximum number of seconds between successive samples of the counters.