xStack
DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch Web UI Reference Guide
Parameter
Priority 1 (0-255)
Priority 2 (0-255)
Click the Apply button to accept the changes made.
PTP Boundary Port Settings
This window is used to configure the attributes of the PTP boundary clock. The configuration takes effect when the
PTP device is a boundary type.
To view this window, click L2 Features > PTP > PTP Boundary Port Settings, as shown below:
The fields that can be configured are described below:
Parameter
Unit
From Port / To Port
Description
This is used in the execution of the best master clock algorithm. Lower values take
precedence. The range is from 0 to 255. Zero indicates the highest precedence.
This is used in the execution of the best master clock algorithm. Lower values take
precedence. In the event that the operation of the BMC algorithm fails to order the
clocks based on the values of Priority1, the clock's class and the clock's accuracy; the
Priority 2 will allow the creation of lower values compared to the other devices. The
range is from 0 to 255. Zero indicates the highest precedence.
Figure 5-128 PTP Boundary Port Settings window
Description
Select the switch unit to configure.
Select the port range to use for this configuration.
185