D-Link DWS-1008 Cli Reference Manual page 34

8 port 10/100 wireless switch with power over ethernet
Hide thumbs Also See for DWS-1008:
Table of Contents

Advertisement

Field
Product Name
System Name
System Countrycode Country-specific 802.11 code required for AP operation.
Total Power Over
Ethernet
System Location
System Contact
System IP
System idle timeout
System MAC
Boot Time
Uptime
Fan status
Temperature
PSU Status
D-Link DWS-1008 CLI Manual
DWS model number.
System name (factory default, or optionally configured with set system
name).
(configured with set system countrycode)
Total power that the DWS-1008 is currently supplying to its directly connected
access points, in watts.
Record of the DWS switch's physical location (optionally configured
with set system location).
Contact information about the system administrator or another person to
contact about the system (optionally configured with set system contact).
Common interface, source, and default IP address for the DWS-1008, in
dotted decimal notation (configured with set system ip-address).
Number of seconds MSS allows a CLI management session (console, Telnet,
or SSH) to remain idle before terminating the session. (The system idle
timeout can be configured using the set system idle-timeout command.)
DWS-1008 media access control (MAC) machine address set at the factory,
in 6-byte hexadecimal format.
Date and time of the last system reboot.
Number of days, hours, minutes, and seconds that the switch has been
operating since its last restart.
Operating status of the three switch cooling fans:
• OK—Fan is operating.
• Failed—Fan is not operating. MSS sends an alert to the system log every
5 minutes until this condition is corrected. Fan 1 is located nearest the front
of the chassis, and fan 3 is located nearest the back.
Status of temperature sensors at three locations in the DWS-1008 switch:
• ok—Temperature is within the acceptable range of 0° C to 50° C
(32° F to 122° F).
• Alarm—Temperature is above or below the acceptable range. MSS
sends an alert to the system log every 5 minutes until this condition is
corrected.
Status of the lower and upper power supply units:
• missing—Power supply is not installed or is inoperable.
• DC ok—Power supply is producing DC power.
• DC output failure—Power supply is not producing DC power. MSS
sends an alert to the system log every 5 minutes until this condition is
corrected.
• AC ok—Power supply is receiving AC power.
• AC not present—Power supply is not receiving AC power.
Description
1

Advertisement

Table of Contents
loading

Table of Contents