How Bottlenecks Are Reported; Limitations Of Bottleneck Detection; Enabling Bottleneck Detection - Brocade Communications Systems Brocade 8/12c User Manual

Brocade network advisor san user manual v11.1x (53-1002167-01, may 2011)
Hide thumbs Also See for Brocade 8/12c:
Table of Contents

Advertisement

How bottlenecks are reported

Bottlenecks are reported through alerts in the Master Log. A bottleneck cleared alert is sent when
the bottleneck is cleared.
NOTE
A bottleneck cleared alert is sent if you disable bottleneck detection on a bottlenecked port, even
though the port is still bottlenecked.
Bottlenecks can be highlighted in the Connectivity Map and Product List. Select Monitor >
Performance > View Bottlenecks. If a port is experiencing a bottleneck, a bottleneck icon is
displayed in the Connectivity Map for the switch and fabric, and in the Product List for the port,
switch, and fabric, as shown in
FIGURE 351

Limitations of bottleneck detection

Using this feature for latency bottleneck detection is not recommended for link utilizations above
85%.
The bottleneck detection feature detects latency bottlenecks only at the point of egress, not
ingress. For example, for E_Ports, only the traffic egressing the port is monitored. For FCoE ports,
bottleneck detection monitors traffic going from the FC side to the CEE side, and does not monitor
traffic going in the reverse direction.

Enabling bottleneck detection

Bottleneck detection is enabled on a switch or fabric basis.
If ineligible ports later become eligible or, in the case of a logical switch, if ports are moved to the
logical switch, bottleneck detection is automatically applied to those ports.
Brocade Network Advisor SAN User Manual
53-1002167-01
Bottleneck detection is supported on 4 Gbps, 8 Gbps, and 16 Gbps platforms.
Bottleneck detection is supported in Access Gateway mode.
Bottleneck detection is supported whether Virtual Fabrics is enabled or disabled. In VF mode,
bottleneck detection is supported on all fabrics, including the base fabric.
Bottleneck port indications
If you enable bottleneck detection on a fabric, the feature is applied to all eligible switches in
the fabric and all eligible ports on the switches.
If you enable bottleneck detection on a switch, the feature is applied to all eligible ports on that
switch.
Figure
351. In the figure, port15 and port22 are bottlenecked.
Bottleneck detection
27
801