5.10.2

Specifying the Measurement Range

Clicking the right-hand mouse button on the window displays the popup menu. When [Add
Range] is selected from the popup menu, the [EDIT] dialog box opens to specify the measurement
range of realtime profile.
Figure 5.101 [EDIT] Dialog Box
When the expansion profiling unit is connected to the emulator, it is possible to measure the
profile information within the 6-Mbyte ranges in total. When the expansion profiling unit is not
connected to the emulator, it is possible to measure the profile information within the 2-Mbyte
ranges in total.
In the emulator, 512 Kbytes are considered as a unit to acquire the profiling information on all the
functions in the eight-block areas. Addresses to be specified for each block need not be adjacent.
When the expansion profiling unit is connected to the emulator, 16 blocks of 512 Kbytes are
added and the 24-block areas can be measured in total.
The measured data in each block is displayed on each page of the [Realtime Profile] window. To
switch the page to be displayed, select that page and click the [OK] button in the [Select Page]
dialog box that is opened by selecting [Select Page] from the popup menu of the [Realtime
Profile] window.