• Click the [OK] button.
• The first point display in the State line changes from Disable to Enable.
• The first point display in the Condition line changes from None to Address =
H'00001084 pc.
• Set the program counter and stack pointer values (PC = H'00000800 and R15 = H'00010000)
that were set in section 6.8, Setting Registers, in the [Register] window. Click the [Go] button.
• If program execution is failed, reset the device and execute again the procedures above.
The program runs and then stops at the condition specified under event channel 1.
Figure 6.38 [Source] Window at Execution Stop (Onchip Eventpoint Channel 1)
329