Renesas SH-4A User Manual page 234

Microcomputer development environment system
Hide thumbs Also See for SH-4A:
Table of Contents

Advertisement

(1) [Probe] dialog box
Double-clicking the [Probe] event channel displays this dialog box. Conditions of the eventpoint
can be set on the [Condition] and [Action] pages.
(a) [Condition] page:
Specifies four external probe signal conditions via the external probe cable.
[Operation]:
[Probe 1 to 4]:
210
Figure 5.51 [Probe] Dialog Box ([Condition] Page)
Specifies how to combine the probe signal conditions.
[AND]: Determines whether or not the condition is satisfied by AND
operation of the probe signal condition.
[OR]: Determines whether or not the condition is satisfied by OR operation
of the probe signal condition.
Specifies the probe signal conditions.
[Don't care]: Specifies no probe signal condition.
[High]:
Satisfies the condition when the probe signal is high.
[Low]:
Satisfies the condition when the probe signal is low.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sh4al-dspE200f

Table of Contents