Renesas SH-4A User Manual page 199

Microcomputer development environment system
Hide thumbs Also See for SH-4A:
Table of Contents

Advertisement

Table 5.1 lists the conditions of Event Condition.
Table 5.1 Types of Event Conditions
Event Condition Type
Address bus condition (Address)
Data bus condition (Data)
Bus state condition
(Bus State)
Window address condition
System bus
LDTLB instruction event condition
Count
Branch trace condition
(Branch trace)
Software trace
Action
Table 5.2 lists the combination of conditions that can be set by Ch1 to Ch12 and software trace
channels.
Description
Breaks when the MPU address bus value or the program
counter value matches the specified value.
Breaks when the MPU data bus value matches the specified
value. Byte, word, or longword can be specified as the
access data size.
There are two bus state condition settings:
Bus state condition: Breaks or acquires a trace when the
data bus or the X-Bus or Y-Bus address bus of the MPU is
matched.
Read/Write condition: Breaks or acquires a trace when the
specified read/write condition is matched.
Breaks or acquires a trace when the data in the specified
memory range is accessed.
Breaks or acquires a trace when the address or data on the
system bus is matched.
Breaks when the MPU executes the LDTLB instruction.
Breaks when the conditions set are satisfied the specified
number of times.
Breaks or acquires a trace when a branch occurs with the
condition specified by the MPU. (By default, trace acquisition
is enabled).
Selects whether or not the software trace is acquired.
Selects the operation when a condition, such as setting a
break, trace, or performance start or end, is matched.