(3) [Data] page
Set a data condition.
[Don't care]:
Detects no data when this box is checked.
[Setting]:
Detects the specified data.
[Point]: Specifies single data (not available when [Don't care] has been checked).
[Range]: Specifies a data range (not available when [Don't care] has been checked).
[From]: Enter single data or the minimum value of the data range (not available when
[Don't care] has been checked).
[To]:
Enter the maximum value of the data range (only available when [Range] has
been selected).
Note: Along with setting the data range, the minimum and maximum values can be set in the
[From] and [To] options, respectively.
238
Figure 5.70 [Trace Filter] Dialog Box ([data] Page)