Range Memory Access Trace Functions:
The memory access within the specified range is acquired by a trace. The read cycle, write
cycle, or read/write cycle can be selected as the bus type, ASID value, or bus cycle for
trace acquisition.
[Setting Method]
To open the [Event condition 5] or [Event condition 6] dialog box, double-click on the Ch5
(OA) or Ch6 (OA) column of the [Event] window.
Remove the check mark of the [Don't care] check box in the [Window address] page and
enter the memory range to be set.
Figure 1.18 [Window address] Page
30