At 400 ns, the maximum time that can be measured is about 61 hours.
To change the minimum unit, select [Set] from the popup menu of the [Realtime Profile] window
and open the [Properties] dialog box.
Note: Be sure to set the following when using the realtime profiling function:
• [Acquisition] dialog box that is opened by selecting [Set] from the popup menu of the
[Trace] window:
[Trace type]: Select [AUD Trace].
[Trace Extend Mode]: Uncheck the [Trace data with PPC] check box.
• Ch12 of the [Eventpoint] window:
[Branch event] sheet: check all the branch conditions.
[Action] sheet: Check [Acquire trace].
These settings above are default when the emulator is activated.