NOTE
The dpm hold command should be used to check the status of DPM operation on the console. After
entering dpm hold state of the DA16200, performing normal operations other than for debugging
purposes is not permitted.
6.5
Current Measurement
To measure the current wavef orm, connect the EVB's current measurement point (P2) with the
measurement instrument. For more detailed inf ormation on the Sleep modes, see the Low Power
Operation Mode section in the DA16200 Datasheet Ref .
6.5.1
Test Setup - KEYSIGHT 14585A
Figure 48
shows a typical test setup environment.
Figure 48: Current Test Environment with 14585A
6.5.2
Test Setup with EVK PRO Board
EVK Pro board is a simple evaluation board without any additional devices to measure current.
Figure 49: Current Test Environment with EVK PRO for DA16200
1. To measure current with DA16200 EVK PRO board, connect the two boards with the PCI
connector.
2. Open the two jumpers (P2) of the power line on the DA16200 EVB as shown in
3. Power is supplied f rom the EVK PRO board, and current consumption of DA16200 can be
measured.