(4) Specifying Conditions or Modes for Acquiring Trace Information
The capacity of the trace buffer is limited. When the buffer becomes full, the oldest trace
information is overwritten. Setting the trace acquisition condition allows acquisition of useful
trace information and effective use of the trace buffer.
The trace information acquisition conditions are implemented by eventpoints and acquisition start,
acquisition end, and acquisition can be controlled. For setting eventpoints, refer to section 5.6,
Using the Eventpoints.
The trace information acquisition mode is set in the [Internal/AUD/Usermemory acquisition]
dialog box that is displayed by selecting [Set...] from the popup menu.
220