Graphical Overview Of The Safety Application Interface; Declaration Of Used Variables - ABB AC500-S Safety User Manual

Hide thumbs Also See for AC500-S:
Table of Contents

Advertisement

7.4.2 Graphical overview of the safety application interface

The safety inputs for the two-hand control (S2_S_Switch1 and S3_S_Switch2) are connected to
the two-hand control type II.
Fig. 132: Graphical overview of the exemplary two-hand control with EDM

7.4.3 Declaration of used variables

Table 100: Inputs
Name
S1_S_EStopIn
S2_S_Switch1
S3_S_Switch2
K1_S_EDM1
K2_S_EDM2
S0_Reset
Process
2020/06/19
Data type
Description
BOOL
Emergency stop button S1
BOOL
Switch S2 related to push button 1 of two hand control
BOOL
Switch S3 related to push button 2 of two hand control
BOOL
Feedback from external device K1 (actuator)
BOOL
Feedback from external device K2 (actuator)
BOOL
Reset by user via switch S0 (derived from the functional application)
BOOL
Enabling motion by the process (derived from functional application)
3ADR025091M0208, 12, en_US