Advertisement

Configuration and programming
AC500-S libraries > SafetyBlocks_PLCopen_AC500_v22.lib
The FB detects a static Reset signal.
External FB errors: There are no external errors, since there is no error bits/information provided
by the generic actuator.
Error behavior
In the event of an error, the S_SafetyActive output is set to FALSE.
An error must be acknowledged by a rising trigger at the Reset input. To continue the function
block after this reset, the S_OpMode request must be set to TRUE.
Function block-
Table 64: FB-specific error codes
specific error
DiagCode
and status
codes
C002
C003
C004
C005
280
State name
State description and output setting
Acknowl-
Acknowledgment lost while in the safe state.
edge Lost
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = FALSE
Error = TRUE
Monitoring-
S_OpMode request could not be completed within the monitoring
Time
time.
Elapsed
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = FALSE
Error = TRUE
Reset Error
Static Reset detected in state C002 (Acknowledge Lost).
2
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = FALSE
Error = TRUE
Reset Error
Static Reset detected in state C003 (MonitoringTime elapsed).
3
Ready = TRUE
S_SafetyActive = FALSE
S_SafetyRequest = FALSE
Error = TRUE
3ADR025091M0208, 12, en_US