Configuration and programming
AC500-S libraries > SafetyBlocks_PLCopen_AC500_v22.lib
Name
Data type
S_Mode5
BOOL
S_Mode6
BOOL
S_Mode7
BOOL
S_Unlock
BOOL
S_SetMode
BOOL
AutoSetMode
BOOL
Reset
BOOL
ModeMonitorTime
TIME
VAR_OUTPUT
Ready
BOOL
S_Mode0Sel
BOOL
206
Initial value
Description, parameter values
FALSE
Variable or constant.
Input 5 from mode selector switch
FALSE: Mode 5 is not requested by operator.
TRUE: Mode 5 is requested by operator.
FALSE
Variable or constant.
Input 6 from mode selector switch
FALSE: Mode 6 is not requested by operator.
TRUE: Mode 6 is requested by operator.
FALSE
Variable or constant.
Input 7 from mode selector switch
FALSE: Mode 7 is not requested by operator.
TRUE: Mode 7 is requested by operator.
FALSE
Variable or constant.
Locks the selected mode
FALSE: The actual S_ModeXSel output is locked
therefore a change of any S_ModeX input does not
lead to a change in the S_ModeXSel output even in
the event of a rising edge of SetMode.
TRUE: The selected S_ModeXSel is not locked; a
mode selection change is possible.
FALSE
Variable (or constant FALSE, if AutoSetMode =
TRUE)
Sets the selected mode
Operator acknowledges the setting of a mode. Any
change to new S_ModeX = TRUE leads to S_Any-
ModeSel/S_ModeXSel = FALSE, only a rising Set-
Mode trigger then leads to new S_ModeXSel =
TRUE.
FALSE
Constant.
Parameterizes the acknowledgment mode
FALSE: A change in mode must be acknowledged by
the operator via SetMode.
TRUE: A valid change of the S_ModeX input to
another S_ModeX automatically leads to a change in
S_ModeXSel without operator acknowledgment via
SetMode (as long as this is not locked by S_Unlock).
FALSE
Ä Table 16 "General input parameters" on page 192
T#0
Constant.
Maximum permissible time for changing the selection
input.
FALSE
Ä Table 17 "General output parameters"
on page 193
FALSE
Indicates that mode 0 is selected and acknowledged.
FALSE: Mode 0 is not selected or not active.
TRUE: Mode 0 is selected and active.
3ADR025091M0208, 12, en_US