DiagCode
8003
8011
8012
8013
8014
2020/06/19
State name
State description and output setting
Wait for
Door is closed and locked, now waiting for operator reset
Reset
Ready = TRUE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = FALSE
Wait for
Waiting for operator to either unlock request or reset.
Operator
Ready = TRUE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = FALSE
Guard Open
Lock is released and guard is open.
and
Ready = TRUE
Unlocked
S_GuardLocked = FALSE
S_UnlockGuard = TRUE
Error = FALSE
Guard
Lock is released but guard is closed.
Closed but
Ready = TRUE
Unlocked
S_GuardLocked = FALSE
S_UnlockGuard = TRUE
Error = FALSE
Safety
Return of S_SafetyActive signal, now waiting for operator
Return
acknowledge.
Ready = TRUE
S_GuardLocked = FALSE
S_UnlockGuard = FALSE
Error = FALSE